CCI brings 40 years of engineering experience and innovation to positioner actuation technology.
The CCI smart positioner features communication capabilities, automatic configuration program, and self-diagnostic functions to increase productivity and efficiency plant operation. Calibration, configuration and self-diagnostics can be performed by using a HARTTM communicator or computer via HARTTM modem.

Easy to Use
The auto-setup function is a fully-automatic configuration program which specifies the actuator and adjusts the zero and span of the valve. The program can be turned on simply from a switch so that adjustments to the valve can be performed quickly and safely in hazardous areas.
Built-in Valve Diagnostics
The following parameters can be monitored by HARTTM communicator or control valve maintenance support system:
- Stick slip
- Cycle count
- Total stroke
- Shut-off count
- Travel histogram
- Max. travel speed
Easy to Install
The CCI smart positioner can be installed to the actuator by using a standardized mounting kit for long linear strokes.
High Reliability
- Positive seating:
The positive seating function completely shuts off the valve if the input signal becomes lower than previously set. This in turn
enhances the full shut-off capabilities of the valves.
- Self-diagnostic: The self-diagnostic function provides the ability to check the status of the positioner at any time and to alert in case of failure.
Single Model for Multiple Specifications
CCI’s smart positioner settings can be changed without replacing any parts. A single model can be modified to suit any application.
- Flow characteristic: Linear, EQ%, quick opening or custom user characteristics (16 points)
- Actuator type: Double or single acting actuator
HARTTM Communication compatible
HARTTM communicator can be used for calibration and configuration as well as self-diagnostics.
Control Signal Input
- 4-20 mA DC Input resistance Approx. 600 ? / 20 mA DC
(voltage between terminals 12V DC)

Approvals
- KEMA/ATEX Intrinsically safe approval II 1 G EEx ia IIC T4
The barriers should be ATEX certified types and comply with the following conditions as follows:
- Input circuit (terminals I IN)
Ui=29V, Ii=95mA (resistively limited), Pi=690mW, Ci=10nF,
Li=220µH
- From the safety point-of-view, the supply/input circuit shall be
considered to be connected to earth.