Information for Suppliers—click here

  CCI Responsible Business
We take our responsibility to the environment and the communities in which we operate very seriously. We believe that these responsibilities can impact positively on profitability, returns, reputation and growth. Click here for more information.
 
Visit IMI Responsible Business

 

What's New

CCI Technology Product Update
CCI brings 40 years of engineering experience and innovation to positioner actuation technology.

The CCI smart positioner features communication capabilities, automatic configuration program, and self-diagnostic functions to increase productivity and efficiency plant operation. Calibration, configuration and self-diagnostics can be performed by using a HARTTM communicator or computer via HARTTM modem.

Easy to Use

The auto-setup function is a fully-automatic configuration program which specifies the actuator and adjusts the zero and span of the valve. The program can be turned on simply from a switch so that adjustments to the valve can be performed quickly and safely in hazardous areas.

Built-in Valve Diagnostics

The following parameters can be monitored by HARTTM communicator or control valve maintenance support system:

  • Stick slip
  • Cycle count
  • Total stroke
  • Shut-off count
  • Travel histogram
  • Max. travel speed

Easy to Install

The CCI smart positioner can be installed to the actuator by using a standardized mounting kit for long linear strokes.

High Reliability

  • Positive seating: The positive seating function completely shuts off the valve if the input signal becomes lower than previously set. This in turn
    enhances the full shut-off capabilities of the valves.
  • Self-diagnostic: The self-diagnostic function provides the ability to check the status of the positioner at any time and to alert in case of failure.

Single Model for Multiple Specifications

CCI’s smart positioner settings can be changed without replacing any parts. A single model can be modified to suit any application.

  • Flow characteristic: Linear, EQ%, quick opening or custom user characteristics (16 points)
  • Actuator type: Double or single acting actuator

HARTTM Communication compatible

HARTTM communicator can be used for calibration and configuration as well as self-diagnostics.

Control Signal Input

  • 4-20 mA DC Input resistance Approx. 600 ? / 20 mA DC
    (voltage between terminals 12V DC)

Approvals

  • KEMA/ATEX Intrinsically safe approval II 1 G EEx ia IIC T4
    The barriers should be ATEX certified types and comply with the following conditions as follows:
  • Input circuit (terminals I IN)
    Ui=29V, Ii=95mA (resistively limited), Pi=690mW, Ci=10nF,
    Li=220µH
  • From the safety point-of-view, the supply/input circuit shall be
    considered to be connected to earth.

For additional technical information click on the .pdf file below to view the complete product brochure or to e-mail to ask The Valve Doctor click here.

 More more information about the CCI Smart Positioner, click here

Ask the Valve Doctor, click here

www.ccisolutionsonline.com




Customer Newsletter

Enter your e-mail address to receive our customer newsletter
Choose your industry
Oil & Gas Power


Find a sales representative in your location